Home/Novotest NDT Equipment/Hardness Testers/Combined Hardness Tester NOVOTEST T-UD2
Back to Hardness Testers
Combined Hardness Tester NOVOTEST T-UD2

Combined Hardness Tester NOVOTEST T-UD2

Industrial inspection equipment

Overview

The combined hardness tester integrates the advantages of UCI and Leeb methods, enabling users to test both large rough-surfaced products and small, complex-shaped samples, making it ideal for non-destructive metal hardness testing across various materials and scales. Component qualification supports material conformity assessment heat treatment verification and service readiness across engineered parts helping teams make confident acceptance decisions.

Combined Hardness Tester NOVOTEST T-UD2 is configured with 2 removable probes: ultrasonic contact impedance (UCI) and dynamic rebound (Leeb), There are almost no restrictions for hardness testing (by weight configuration structure degree of mechanical and thermal treatment etc.), and To evaluate changes in the hardness of the hardened layer depth articles and the effect of surface stress to support reliable day-to-day inspection work in demanding operating conditions.

Key technical details include Measurement Methods: UCI + Leeb, Hardness Scales: HV, HB, HRC, HRA, HRB, HS, Measurement Range: 200-960 HV (UCI), 170-960 HLD (Leeb), and Accuracy: ±4 HV (UCI), ±8 HLD (Leeb), helping teams evaluate fitment, access requirements, and inspection coverage before deployment.

This product is suited to applications such as General manufacturing QC, Maintenance inspections, and Field testing, where repeatable imaging, measurement, or defect detection performance is important.

Key Highlights

  • 2 removable probes: ultrasonic contact impedance (UCI) and dynamic rebound (Leeb)
  • There are almost no restrictions for hardness testing (by weight configuration structure degree of mechanical and thermal treatment etc.)
  • To evaluate changes in the hardness of the hardened layer depth articles and the effect of surface stress
  • Wide range of hardness value
  • Convenience and ease in operation
  • Graphical contrast display with backlight
  • Automatic recognition of probe
  • Extended temperature range (cold-resistant down to -20 °C)
  • Device has internal memory and allows user to transmit data to PC

Request a Quote

Get pricing, availability, and technical guidance.

Request Quote

Response within 1 business day.

Technical Specifications

Measurement MethodsUCI + Leeb
Hardness ScalesHV, HB, HRC, HRA, HRB, HS
Measurement Range200-960 HV (UCI), 170-960 HLD (Leeb)
Accuracy±4 HV (UCI), ±8 HLD (Leeb)
DisplayLCD
Memory200 measurements
InterfaceUSB
Power SupplyRechargeable battery
Weight300g
UCI probe types1kgf (10N) 2.2 lbf, 5kgf (50N) 11lbf, 10kgf (98N) 22lbf
Leeb probe typesD, DC, DL, C, D+15, E, G
IndenterDiamond indenter (UCI), Hardened ball (Leeb)
Hardness scaleUCI probe: HRC, HB, HV, MPa, Leeb probe: HRC, HB, HV, HLD, MPa
Measurement hardness range: Rockwell, HRC Brinell, HB Vickers, HV20 – 70, 90 – 650, 230 – 940
Measuring accuracyHRC: 2HRC, HB: 10HB, HV: 15HV
StandardsASTM A1038, ASTM A956
Measuring directionAny direction 360°
MaterialsUCI probe – pre-calibrated for steel. Leeb probe – pre-calibrated for steel, alloy steel, stainless steel, cast iron. Additional custom scales and materials for calibration.
Storage of measurement results256
LanguageEnglish, Spanish, Portuguese, French, Russian, *additional languages available by request
Operating temperature range, ° C-20 … +40
Power supply2pcs AA batteries
Dimensions, mm122x76x37
Weight of electronic unit with battery, no more, kg0.25
Batteries life, not less, h20
Package gross weight, kg2

Applications

General manufacturing QC

Maintenance inspections

Field testing

Small workshops

Educational institutions

Basic hardness verification

Request Product Information

Fill out the form below and our team will get back to you with detailed information about the Combined Hardness Tester NOVOTEST T-UD2.

Request a Quote

Interested in Combined Hardness Tester NOVOTEST T-UD2? Fill out the form below and our team will get back to you within 24 hours.

+91

By submitting this form, you agree to our privacy policy. We respect your privacy and will never share your information.

Frequently Asked Questions

How does the NOVOTEST T-UD2 simplify hardness testing across components with different geometries?

The NOVOTEST T-UD2 combines UCI and Leeb technologies within a single instrument, allowing inspectors to evaluate both thin precision components and large heavy structures without changing equipment. This versatility enables seamless inspection across diverse applications while improving measurement consistency and inspection efficiency.

Why is the NOVOTEST T-UD2 an ideal solution for third-party inspection agencies?

Inspection organizations frequently encounter components that vary significantly in size, material, and surface condition. The T-UD2 eliminates the need to carry separate hardness testers by allowing inspectors to select the most appropriate testing method for each application, improving operational flexibility and reducing equipment investment.

Can the NOVOTEST T-UD2 inspect thin components as well as heavy industrial equipment?

Yes. Using its UCI probe, the instrument can accurately evaluate thin sections, surface-hardened components, gears, turbine blades, and complex geometries, while the Leeb probe is ideal for large castings, forgings, and massive industrial structures. This dual capability enables one instrument to address a broad spectrum of inspection requirements.

How does the NOVOTEST T-UD2 improve inspection standardization across multiple facilities?

The instrument supports consistent measurement procedures, digital data storage, and repeatable testing methodologies, enabling organizations operating multiple manufacturing plants or project sites to standardize hardness testing practices, simplify quality documentation, and improve traceability during audits.

Why is the NOVOTEST T-UD2 a strategic investment for Indian manufacturing industries?

For manufacturers seeking to improve inspection efficiency while reducing capital expenditure, the NOVOTEST T-UD2 delivers two internationally recognized hardness testing methods in one portable platform. This increases operational versatility, supports broader inspection capabilities, and maximizes return on investment across multiple industrial applications.