Home/Novotest NDT Equipment/Ultrasonic Thickness Gauges/Ultrasonic Thickness Gauge NOVOTEST UT-2A (A-Scan)
Back to Ultrasonic Thickness Gauges
Ultrasonic Thickness Gauge NOVOTEST UT-2A (A-Scan)

Ultrasonic Thickness Gauge NOVOTEST UT-2A (A-Scan)

Industrial inspection equipment

Overview

The NOVOTEST UT-2A (A-Scan) Ultrasonic Thickness Gauge is designed for industrial thickness measurement where waveform analysis, probe flexibility and detailed inspection control are important. Its A-scan capability allows trained inspection personnel to examine ultrasonic signals in addition to obtaining digital thickness readings. This makes the instrument relevant to inspection applications that require more than basic digital thickness measurement. The UT-2A supports A-scan, B-scan, digital, manual and thickness-limit control modes. Its published specifications include a measurement range of approximately 0.4–1,500 mm in steel, depending on the selected probe and material characteristics. The instrument offers a 3.5-inch colour display, measurement resolution of 0.01 mm and a built-in rechargeable battery. It also supports multiple measurement methods, including echo, echo-echo and peak-to-peak, depending on the selected configuration. The UT-2A is suitable for consideration by Indian NDT inspection agencies, manufacturing facilities, fabrication contractors and industrial maintenance teams. It can support thickness measurements on suitable metal components, including pipes, plates, tanks and other structures where access is available. Its waveform display and multiple operating modes help trained users assess measurement conditions and select appropriate inspection settings. Buyers considering the NOVOTEST UT-2A should evaluate the required probe frequency, material characteristics, thickness range and inspection procedure. Optional probes, including through-coating and high-temperature configurations, may be relevant to particular applications. The required calibration blocks, couplant, data-transfer options and reporting workflow should also be reviewed before finalising the equipment configuration.

Key Highlights

  • Wide range of measuring thicknesses
  • Function of thickness gauge and flaw detector
  • Convenience and ease in operation
  • B-scan mode which allows user to get the product profile like a picture that is easy to read
  • Minimum number of controls
  • Select the type of probe from archive
  • Preset velocity of ultrasound
  • High brightness color display
  • Indicator the presence of acoustic contact

Request a Quote

Get pricing, availability, and technical guidance.

Request Quote

Response within 1 business day.

Technical Specifications

Measurement Range0.75-500mm (steel)
Accuracy±0.05mm or ±0.5%
Resolution0.01mm
Display3.5" color TFT
A-Scan DisplayFull waveform with zoom
Data Storage50,000 readings
ConnectivityUSB, Bluetooth
Power SupplyBuilt-in Li-ion Battery
Operating Time12+ hours
Weight350g
Dimensions160 x 90 x 40mm
Probe type range for steel, mm: Probe 10MHz – P112-10-2×3, Probe 10MHz – P112-10-6 / 2, Probe 5MHz – P112-5-10 / 2, Probe 2,5MHz – P112-2,5-12 / 2, Probe 2MHz – P112-2-20 / 2, Probe 1,25MHz – P112-1.25-20 / 20.4-15, 0.45-300, 0.8-500, 2.5-1000, 3-1200, 4-1500
Probe dimensions, mm: Probe 10MHz – P112-10-2×3, Probe 10MHz – P112-10-6 / 2, Probe 5MHz – P112-5-10 / 2, Probe 2,5MHz – P112-2,5-12 / 2, Probe 2MHz – P112-2-20 / 2, Probe 1,25MHz – P112-1.25-20 / 24×9×60, D12×15, D17×20, D20×21, D30×28, D30×35
Dimensions of probe contact area/crystal, mm: Probe 10MHz – P112-10-2×3, Probe 10MHz – P112-10-6 / 2, Probe 5MHz – P112-5-10 / 2, Probe 2,5MHz – P112-2,5-12 / 2, Probe 2MHz – P112-2-20 / 2, Probe 1,25MHz – P112-1.25-20 / 22×7/2×3, D9/D6, D14/D10, D16/D12, D24/D20, D24/D20
Optional probes: 5MHz high-temperature probe (echo) 10/2, 2,5MHz probe (echo-echo) 12/2 for through coating, 5MHz probe (echo-echo) 10/2 for through coating, 10MHz probe (echo-echo) 6/2 for through coating, 5MHz probe (echo-echo) 10/2 for through coating, underwater, 10 m cable, 5MHz probe (echo-echo) 10/2 for through coating, underwater, 20 m cable, 5MHz probe (echo-echo) 10/2 for through coating, underwater, 30 m cablerange 0,8 – 300 mm, surface temperature up to 250 °С/482 °F range 6 – 30 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 2 – 12 mm, coating thickness range – up to 0,6 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm range 3,5 – 26 mm, coating thickness range – up to 1 mm
Compatible probe typesDual-element Single-element (including probes of other manufacturers) EMAT
Measurement units1 –mm, inch, μs 10 MHz
Resolution, mm/inch0,01/0,001
Ultrasound velocity adjustment range, m/s700-17000
Ultrasound velocity in the standard device sample, m/s6070 ± 70
Operating modesA-scan, B-scan, Digital mode, Control mode, Manual
Measurement methodsEcho, Echo Echo (Dual Echo), Peak-peak
PC cable connectionOnline – novotest.info, Offline – NOVOTEST AWP
Wireless connection with Android gadgets via NOVOTEST Lab AppNo
Storage capacity of measurement results7000 and more (Limited only by the memory card)
Menu LanguageEnglish, Russian, *additional languages available by request
Weight of the electronic unit, not more, kg0,5
Dimensions (L x W x H)165x90x50 mm
Time of continuous work, not less than, h10 (up to 20 by special order)
Operating temperature range for the electronic unit, ° C-20 to +40
Air moisture, no more98 %, at 35 °С

Applications

Corrosion mapping

Composite material inspection

Multi-layer thickness measurement

Critical structure monitoring

Quality assurance testing

Request Product Information

Fill out the form below and our team will get back to you with detailed information about the Ultrasonic Thickness Gauge NOVOTEST UT-2A (A-Scan).

Request a Quote

Interested in Ultrasonic Thickness Gauge NOVOTEST UT-2A (A-Scan)? Fill out the form below and our team will get back to you within 24 hours.

+91

By submitting this form, you agree to our privacy policy. We respect your privacy and will never share your information.

Frequently Asked Questions

Why does the NOVOTEST UT-2A incorporate A-Scan technology?▼

Unlike conventional thickness gauges that display only numerical values, the NOVOTEST UT-2A provides an A-Scan waveform, enabling inspectors to visually interpret ultrasonic signals. This additional diagnostic capability significantly improves measurement confidence when inspecting complex materials, coated surfaces, and components exhibiting irregular internal structures.

How does A-Scan visualization assist experienced NDT professionals?▼

A-Scan technology allows inspectors to distinguish genuine material reflections from false indications, optimize transducer positioning, and validate measurement quality. This enhances diagnostic accuracy during inspections of welds, castings, forgings, pressure equipment, and critical structural components.

Can the NOVOTEST UT-2A perform more than conventional thickness measurement?▼

Yes. Beyond standard wall-thickness evaluation, the UT-2A incorporates advanced operating modes such as A-Scan, B-Scan, profile visualization, and professional measurement algorithms, enabling experienced users to perform comprehensive material assessment and detailed defect evaluation using a single instrument.

Which professionals derive the greatest benefit from the NOVOTEST UT-2A?▼

The instrument is particularly valuable for certified NDT inspectors, QA/QC engineers, inspection consultants, EPC contractors, pressure vessel manufacturers, refinery maintenance teams, and third-party inspection organizations that require advanced ultrasonic analysis for mission-critical assets.

Why is the UT-2A preferred for technically demanding inspection projects?▼

Its advanced signal interpretation capabilities provide greater analytical confidence when evaluating complex geometries, variable wall sections, coated materials, and high-value industrial components, enabling more informed engineering decisions and improved inspection reporting.